How to check a QNAP NAS for CPU stability and overheating

CPU Lab in StorageDiag Workbench loads the NAS processor in rounds that follow each other without pauses. A run ends by itself when the score stops changing, or after about five minutes. CPU Lab then shows the peak CPU temperature and how far the core clocks dropped, and BlackBox shows the temperatures and fan speeds over the same minutes. Together they help you judge the cooling and decide what to check next.

  1. Preparesign in as an administrator and pick a quiet time for the NAS
  2. Run CPU Labwatch the index settle round by round
  3. Open BlackBoxfollow the temperature sensors and fan speeds
  4. Read the resultthe verdict, the peak temperature and the clock
  5. Repeatrun longer, or use Lab when other processes get in the way

01Before you start

CPU Lab, Pulse and BlackBox are on the Utilities desktop and monitor the NAS that StorageDiag is installed on. Sign in as an administrator: Pulse and BlackBox open only for administrators.

  • Pick a quiet time. CPU Lab runs its test threads at real-time priority. While it runs, shares, apps and virtual machines can respond slowly or time out.
  • Stopping a run. During the first run after the window opens, the button in the title bar reads Running and is greyed out. Later runs in the same window stop with Stop. Closing the window ends a run started with Run, the first one too. A Lab run keeps going (section 06).
  • Publishing. By default, CPU Lab publishes a result with the verdict clean or throttled on the public CPU board, with the NAS model, the processor and the memory. To keep your runs off the board, open Compare and untick publish automatically, then close CPU Lab and open it again before you click Run. The browser keeps this choice, so untick it in every browser you use. A Lab run (section 06) publishes these two verdicts in every case.
  • Greyed-out Run and Lab. When the StorageDiag daemon runs at the Safe mode or Locked down level, Run and Lab are greyed out and the window shows a notice. An administrator changes the level in Access management, on the Daemon tab.
  • History needs no setup. From the moment the package starts, BlackBox records the state of the NAS every 20 seconds, and temperatures and fan speeds once a minute.

02Run the test

  1. Open CPU Lab: Start menu → Benchmarks → cpuhound, or click the desktop icon of the same name. The Processor card shows the CPU model, the number of threads, the maximum clock speed and the frequency governor.
  2. Click Run in the title bar. Each round runs the compute tests one after another, each first on one thread and then on all logical CPUs the test uses. The table lists the eight tests that make up the index. Rounds follow without pauses. The run ends when the last four rounds agree within 1.5 %, when five rounds in a row bring no tighter spread, or after about five minutes.
  3. After each round, watch the CPH index and the status line with the round number and the spread (round 8 · ±8.6 % → ±1.5 %). The table highlights the test in progress, and the Data computing card draws one tile per logical CPU.
Figure 1. CPU Lab during a run (values from a recorded run). Round 8 on a NAS with a 12-thread Core i5-1235U. The index is still moving: the status line shows the spread of the last rounds against the 1.5 % target.

In the table, a red Wait cell marks a test that waited for the CPU for more than 5 % of its running time. During the run, a rose contended chip on the Data computing card means that an all-core test waited that long. With the default real-time scheduler settings, the kernel keeps about 5 % of every second for other tasks, so these marks are common. The contended verdict needs more: the median wait of the last four rounds above about 10 %. The run in figure 1 ended as throttled (figure 3).

When the processor lowers its clock as it heats up, the index falls over the first rounds and then levels off. In the run in figure 1, round 1 scored 9 762, and from round 6 on the scores stayed between 7 160 and 7 808. The settled score is the performance this NAS keeps with its own cooling, in the conditions of the test.

On a NAS with four logical CPUs or fewer, CPU Lab leaves one CPU to the system. After the run, its tile turns dark (the legend says dark = left to the OS), and the NAS's total CPU load stays below 100 %.

03Watch temperatures and fan speeds

CPU Lab shows the temperature only when the run ends. BlackBox records sensor readings and fan speeds all the time, so you can open it beside CPU Lab during the run or after it:

  1. Open BlackBox: Start menu → Monitoring → BlackBox.
  2. In the title bar, choose Charts, the 1h range and the Absolute scale. On this scale the temperature and fan-speed axes start at zero.
  3. For temperatures alone, click Temp in the title bar: one panel with up to twelve sensors.
  4. For temperatures, fans and CPU load together, as in figure 2, use the series picker instead. Open it with the tab at the left edge. In the Thermal group, tick the Temperature row and click Fan speed (a NAS with several fans has a button for each). In the CPU group, click sys in the CPU busy row. Each unit (°C, rpm, %) gets its own panel on a shared time axis. A choice in the picker replaces the Temp view.
Figure 2. BlackBox during three CPU Lab runs (example data from a NAS with a four-core, eight-thread CPU). The package and core sensors climb to about 76 °C and level off. The enclosure sensor system1 rises by a few degrees, and the fan speeds up as the temperature rises.
  • Sensors. package and core0, core1, … are the sensors of an Intel CPU; an AMD processor reports tctl. When the kernel exposes no processor sensor, the CPU temperature that QNAP reports appears as cpu. system1 and similar names are QNAP's enclosure sensors. Other devices, such as a network card, can add sensors of their own. Fans are named by number; a CPU fan is cpu1.
  • One point a minute. BlackBox reads temperatures and fan speeds once a minute, so a run of a few minutes gives only a few points. Section 05 shows how to keep the load on for longer.
  • Heat map. Heat map in the title bar draws each sensor as a row of coloured cells: amber from 65 °C, red from 80 °C.
  • Events. BlackBox marks Critical temperature on the timeline when a core, the package or cpu reaches 90 °C, an enclosure sensor 60 °C, a network-card sensor usually 100 °C, and any other sensor, AMD's tctl included, 85 °C. It marks Fan stopped when a fan that QNAP reports as present reads 0 rpm.
  • Live clock speeds. Pulse (Start menu → Monitoring → Pulse, CPU tab) refreshes every logical CPU every two seconds: Busy, Current clock (⚡ above the base clock), Min, Max and Governor. A large clock drop under steady load can point to a performance limit. Judge it together with the temperature and the governor.
  • Kernel log. Start menu → Live logs → Kernel Log · LIVE opens the window of that name, which shows new kernel messages as they arrive. A line such as Package temperature above threshold, cpu clock throttled gets the CPU Thermal Throttle pattern. A [Hardware Error] line is a hardware error reported by the processor or the firmware, usually a machine check. Decode it in MCE Decoder (Start menu → Analysis).

04Read the result

When the run ends, the CPH index card shows the verdict and the number of rounds. The Processor card gets a Thermal line: the peak CPU temperature and the lowest clock any core dropped to, as a percentage of that core's own peak. Both come from the last round.

Figure 3. The result of the run in figure 1. throttled · 14 rounds, index 7 589 (±5.2 %) and Thermal: 98 °C peak · clock 90 %. The processor went past CPU Lab's 95 °C threshold, and its slowest core kept 90 % of its own peak clock. The result was published, so the card shows its place on the board.
CPU Lab's verdicts
VerdictWhat happenedOn the board
cleanEvery core kept at least 90 % of its own peak clock, the CPU stayed below 95 °C, and the wait for CPU time stayed below the contended threshold.yes
throttledA core's clock fell more than 10 % below its own peak, or the hottest CPU sensor reached 95 °C. The score is the CPU's performance in that state.yes
contendedOther processes held the CPU, so the test waited for CPU time. The score is a lower bound.no
untrustedOther processes held the CPU while the clock was also dropping or the CPU had reached 95 °C.no
indicativeThe score did not settle: the spread of even the four best-agreeing consecutive rounds stayed above ±5 %. Only a run that would otherwise be clean gets this verdict.no

CPU Lab and BlackBox use fixed temperature thresholds, the same for every processor. The real limit depends on the processor model and the NAS design, so a reading of 90 or 95 °C alone does not prove overheating. Compare the temperature with the specifications of the CPU and the NAS, with the clock speed and with the kernel log.

  • Heat or a clock limit. A throttled verdict comes from heat or from a clock drop. With a peak above 90 °C, as in figure 3, check the cooling and compare the peak with the processor's specifications. A clock drop with a peak in the 60s or 70s can point to a power limit or the governor.
  • Check the temperature on a clean run too. clean allows a peak below 95 °C. A run that peaks at 90 °C can be clean in CPU Lab and still reach BlackBox's Critical temperature threshold.
  • The CPU drawing. On the Data computing card, an amber outline means throttling and a rose outline means waiting for CPU time; the legend under the drawing names each state. The Wait column turns red above 5 %. With the default real-time scheduler settings, part of that wait can be the kernel's own reserve (section 02).
  • Index. The CPH index gives a single-thread score and an all-core score. On this scale, one thread of a current mid-range NAS processor scores about 1 000. The ring beside the index shows the precision the run reports.

05Load the CPU for longer

A run lasts from about one to five minutes, and with good cooling the score can settle in four to six rounds. To watch the temperatures for longer, start each run as soon as the previous one ends:

  1. When the verdict appears on the CPH index card, click Run again. On a NAS that heats up, three runs can take about a quarter of an hour, as in figure 2. If the score settles quickly, repeat the test until BlackBox shows ten minutes of load.
  2. Watch BlackBox. With good cooling, the CPU temperatures level off and the fan holds a higher speed. If the temperatures are still rising at the end of the last run, the NAS has not reached a steady temperature yet. Check whether the clock is dropping or the model's temperature limits are exceeded.
  3. Open Compare, then the This unit tab. It lists the last 40 runs of this NAS with the date, the type (Run or Lab), the verdict and the index. Click a run to compare its all-core results, test by test, with the newest other run of the same build of CPU Lab's test program. A run of another build carries the tag other build. Similar scores across runs mean steady performance under the test conditions. Falling scores with rising temperatures call for a cooling check.

06Test with services stopped (Lab)

A contended or untrusted verdict means that other processes took CPU time from the test. Lab runs the same test with the services stopped:

  1. Close every QTS or QuTS hero tab in the browser: an open panel can start services again.
  2. Click Lab. The panel lists the steps, the data the run writes, how long it takes and the checks. It also names what stops: file sharing, an iSCSI target, App Center packages, scheduled jobs, media, snapshots, replication and antivirus. StorageDiag, the admin panel and helpdesk keep running.
  3. Lab does not start while a virtual machine runs, an iSCSI session is connected, an array or pool is degraded, rebuilding, resyncing or scrubbing, or another CPU or memory test is running. A check that fails turns red and gives the reason.
  4. Tick the confirmation box and click Start Lab run.
Figure 4. The Lab panel before a run (example services and checks). Estimated time: one to three minutes to stop the services (at most 30 minutes), up to five minutes for the test, and one to three minutes to start the services again.

Lab sets the governor to performance, stops the services and waits 30 seconds for the CPU to settle. Then it runs the same test, puts the previous governor back and starts the services again. A Lab run keeps going on the NAS after you close the browser. Cancel ends the test and starts the services again. When the run ends, check that your shares and apps work again.

07Symptoms and what to do

What CPU Lab and BlackBox show, and what to do
What you seeWhat it meansWhat to do
clean, a peak well below 90 °C, steady temperatures and a fan holding a higher speedThe cooling copes with the load of this test.Keep the result for later comparisons.
throttled with a peak of 95 °C or more and the fans at high speedThe CPU reached CPU Lab's temperature threshold. The clock figure shows the clock it kept.Compare the temperature with the model's limits and check the cooling (section 08). Repeat the test after you fix a problem.
throttled with a peak in the 60s or 70sA power limit or the governor may be lowering the CPU's clock.Check Governor in Pulse. Lab runs with performance.
A fan at 0 rpm, or Fan stoppedA possible fault in the fan, its connection or the speed reading.Stop the test (section 01). Check that the fan turns and is connected properly. Replace it if it is faulty.
A fan that does not speed up under loadThe fan settings or the fan itself need checking.Raise the fan speed (section 08). If the fan does not respond, check it before you replace it.
Critical temperature comes back after cleaning, at a normal room temperatureA possible cooling fault, such as a worn fan or poor heatsink contact.Check the model's temperature limits. If the symptoms point to a cooling fault, take the NAS to a repair service.
The NAS restarts during a run or still does not respond after itThe cause needs more diagnosis: the power supply, motherboard, CPU, memory and temperature are all candidates.Read the kernel log and BlackBox and test the RAM, then report the problem to a repair service with these results.
[Hardware Error] lines in the kernel log during the runThe processor or the firmware reported hardware errors.Decode the lines in MCE Decoder, which names the subsystem (memory, CPU or bus), and send the result to a repair service.
contendedOther processes took the CPU time the test needed.Repeat the test with Lab (section 06).

CPU Lab does not stop when the temperature rises: it goes on measuring at the lower clock. The processor has its own thermal protection, but do not keep testing once you know the cooling has a problem. If BlackBox shows Fan stopped or 0 rpm, stop the run with Stop (a Lab run with Cancel; during the first run, close the CPU Lab window) and start no other until you have checked the fan. If the NAS hangs, find the cause before you test again.

CPU Lab measures performance and does not check the results of its calculations, so a steady index does not prove that the processor works correctly. Calculation errors can come with application crashes, restarts and machine checks, so read the kernel log too. Faulty memory causes similar symptoms: test the RAM before you suspect the processor.

08Cool a NAS that runs hot

  • Dust. Remove dust from the heatsink, the fans and the air intakes.
  • Fans. Check that they run and speed up under load (BlackBox, Fan speed). If they stay slow while the CPU is hot, raise their speed in the Smart Fan settings of QTS or QuTS hero: Control Panel → System → Hardware → Smart Fan.
  • Airflow. Leave space in front of the intakes and behind the exhaust. Keep the NAS out of closed cabinets and away from other hot equipment. Lower the room temperature if you can.
  • Heatsink. Leave reseating the heatsink or replacing its thermal paste to a repair service or someone experienced in servicing NAS units.
  • Retest. After each change, repeat section 05 and compare the peak temperature, the fan speed and the index with the earlier runs.