Troubleshooting NAS performance: slow reads and writes, step by step

Slow reads and writes on a NAS can have many causes: faulty memory that corrupts data or causes the device to freeze, a failing drive, a faulty or dusty SATA port or backplane, a fragmented or nearly full volume, other disk activity, or the network. This guide helps you investigate them, starting with the hardware, using StorageDiag Workbench & Utilities.

StorageDiag has two operating modes. The first, Workbench, is intended for technical support agents or administrators who manage several servers and need to analyse a QNAP diagnostic log bundle. The second, Utilities, is a traditional diagnostic toolkit in the style of Norton Utilities, used to examine the NAS on which StorageDiag is installed.

Utilities runs directly on the NAS. It includes DriveTime Analyzer for drive analysis, changes in SMART counters, drive authenticity checks, surface and fragmentation scans, and drive stress tests; NetScope, a network toolkit including iperf and Wake-on-LAN; MemHound, a professional RAM tester; Pulse for monitoring running processes; BlackBox, with a heatmap and anomaly charts; and live logs and Dr. Trace. In Workbench mode, you can open a diagnostic bundle from the same NAS or another server to examine LVM and ZFS information, memory usage and modules, drive configurations and SMART data, the kernel log and Dr. Trace analysis.

To switch between Workbench and Utilities, open the Start menu and click the Workbench | Utilities bar. A confirmation message will appear. Once you confirm, open application windows will close and the page will reload. Live logs and NetScope appear only when you are logged in as an administrator.

We will check RAM first, then logs and drive health, compare SMB with iSCSI, run local storage tests, examine space usage and fragmentation, and finally measure network throughput.

  1. RAMMemory integrity testing with MemHound
  2. Logs and SMARTCommunication errors, drive health and HCL compatibility
  3. SMB and iSCSIEstablishing which connections are affected by the slowdown
  4. Drive tests and disk mapLocal measurements, fragmentation and space usage
  5. NetworkThroughput testing with NetScope and iperf3

Before testing, check that your backup is up to date. If drives report read errors, the array is degraded or data is becoming inaccessible, protecting the data takes priority over measuring performance. A stress test does not repair a failing drive.

Record when the slowdown occurs: during reads or writes, on one computer or several, with large files or many small files. Note concurrent NAS tasks, such as backups, RAID rebuilds, indexing, containers and virtual machines. Without this information, successive measurements are difficult to compare.

01Memory

Check RAM stability, particularly when poor performance is accompanied by freezes, restarts or data errors. The procedure is covered in How to test RAM in a QNAP NAS with MemHound.

A test running within the operating system checks the memory allocated to the diagnostic program. It does not test all RAM, including areas used by the operating system and active processes. An error-free result therefore applies to the scope and conditions of that test, not to every memory cell in the device.

A memory integrity test and a benchmark measure different things. The first checks whether data read back matches the data written. The second measures memory performance. The Benchmark and Quality feature is covered in a separate RAM benchmarking guide. A low benchmark score is not, by itself, evidence of a faulty module.

For dual-channel memory, ECC, mixed modules and OOM errors, see the memory section of the MemHound guide.

02Kernel log, SMART and HCL

Kernel log and Dr. Trace

Start by checking whether the system is logging drive communication errors. Repeated link resets, command timeouts and reduced SATA link speeds can explain lower transfer rates even when the drive is still present in the array.1

  1. In Utilities mode, open Live logs → Kernel Log · LIVE or Dr. Trace · LIVE. These windows display current logs from the NAS running StorageDiag.
  2. To prepare a diagnostic analysis, click Run Audit in Dr. Trace, then Generate Diagnostic Report in the window that opens. This feature requires the QNAP Helpdesk application, installed and enabled in App Center. When the audit finishes, StorageDiag makes a session of the bundle and opens Kernel Log (dmesg). For the Dr. Trace verdict, switch to Workbench; the bundle stays loaded. To analyse another NAS, load its diagnostic ZIP bundle in Workbench.
  3. In Kernel Log (dmesg), beside the search field, select .* to enable regular-expression search. The abc mode searches for plain text. Paste the expression below.
  4. Open the related incident in Dr. Trace (Diagnosis) and compare the program's assessment with the log entries on which it is based.
hard resetting link|10B8B|SError|giving up|link is slow|exception Emask

Look particularly for recurring problems involving the same device. The message hard resetting link indicates an attempt to reset the connection; reset failed, giving up indicates that an attempt to restore it failed. Read messages about signal errors, NCQ being disabled or SATA speed reductions together with the surrounding entries. A single reset message does not identify the faulty component.1

Dr. Trace groups related events into incidents and assesses possible causes. For communication problems, these may include the drive, connection, backplane or expander. The percentages shown are the tool's assessment, not a measurement of a component's health or confirmation that it needs replacement.

Do not assume that a port identifier such as ata6 matches the bay number. Before inspecting a drive, cross-check the port, device, bay and serial number. Check drive seating and connections in accordance with the device's service procedure; do not remove drives from an active array one after another as a trial-and-error exercise.

Kernel log from a diagnostic bundle. Port ata6 has SATA communication errors and link-reset attempts. The entry for ata10 includes reset failed, giving up. Workbench highlights make these entries easier to find; the log alone does not establish whether the cause is the drive, connection or backplane. The device name and serial numbers have been masked.
In Workbench mode, open Dr. Trace (Diagnosis), then an incident. Analysis of the same bundle: the tool grouped 402 events over 229 days into one incident involving the connection to drive 12. The assessment shown assigns 59% to the backplane with its SATA controller, 35% to the cable and 6% to the drive. These are the program's assessments of possible causes; the supporting log entries appear below.
Walkthrough · 0:49. Finding SATA errors and analysing an incident in Dr. Trace Kernel Log and Dr. Trace analysis of a diagnostic bundle. Identifying details have been masked.

SMART, historical changes and drive compatibility

In Utilities, open DriveTime Analyzer and the Health tab. The SMART/FARM history helps you establish whether error counters are changing over time. FARM data is read only from Seagate drives that provide it. In the Fleet list, the coloured dot beside each drive shows the worse of two states: the drive's unacknowledged alerts and the value shown in the list.

Select a drive and click View SMART. The window shows Cur, Worst, Thr and Raw: the current normalised value, the worst recorded value, the threshold and the raw value. Raw values can mean different things depending on the manufacturer and model. A large number is not necessarily a count of damaged sectors.2

On the drive's details card, also check its HCL status and assigned class. The HCL indicator concerns model compatibility, not the condition of that particular drive. A listed drive can fail; an absent listing is not, by itself, evidence of a fault. Check the exact model and any notes on the QNAP compatibility list.3

The Desktop, NAS, Enterprise, Surveillance, Archive classes and the Blacklist label provide context, but they do not replace the specification or the reason for a particular classification. For SSDs, also consider sustained write performance: the initial transfer rate may be higher than the rate after the available buffers have been exhausted.4

The Health tab in DriveTime. The Seagate drive in bay 14 has a Critical rating and a reallocated-sector count of 369. Its history contains recurring warnings and a recommendation to protect the data and plan a replacement. Serial numbers have been masked.
SMART readings for the same drive. The HCL ✓ and Enterprise indicators describe the model's compatibility and class, while CRITICAL refers to the condition of this particular drive. Reallocated_Sector_Ct is 369. A drive compatible with the NAS can still fail.
Walkthrough · 0:45. Drive error history and SMART readings in DriveTime Health, the SMART card, HCL compatibility and drive health assessment. Serial numbers have been masked.

If logs or SMART readings suggest a hardware problem, investigate it before benchmarking. Protect the data and review the error history. Neither HCL compatibility nor a SMART PASSED status guarantees that the drive cannot be causing the problem.

03SMB or iSCSI

Establish whether the slowdown occurs over SMB, iSCSI or both. Compare similar operations and workloads. Copying one large file is not equivalent to handling thousands of small files or a virtual machine's random I/O.4

Which protocol is slow
ObservationNext checks
Only SMB is slowCheck the client computer, the types of files being copied, CPU load, and SMB configuration and logs. Do not disable protocol security features merely to improve a benchmark result.
Only iSCSI is slowCheck iSCSI session logs, the initiator, access paths, LUN configuration and client load. If the symptoms suggest an ODX issue, carry out the comparison test below.
Both protocols are slowCheck shared resources: drives, storage pool, CPU, memory and the network connection.

An additional test from another computer helps establish whether the problem extends beyond one client. It does not, on its own, identify a protocol as the cause: changing the client also changes its hardware, operating system and settings.

Windows Server and ODX: a comparison test

ODX (Offloaded Data Transfer) allows supported copy operations to be offloaded to compatible storage. It does not handle every iSCSI read or write. Temporarily disabling it can help compare behaviour with and without offload, but it is not a universal fix for a slow LUN.5

Use this test when incident analysis or technical support identifies ODX as a possible cause. The change applies to the Windows server using the NAS, not to the QNAP itself.

Before making the change, record the current registry value and schedule downtime to restart Windows. The procedure below assumes that FilterSupportedFeaturesMode already exists and is set to 0. If the entry is absent or has another value, agree with the administrator how to make and reverse the change first. Do not replace an unknown configuration with an assumed default.

1. Read the setting in PowerShell, running as administrator:

Get-ItemProperty HKLM:\SYSTEM\CurrentControlSet\Control\FileSystem -Name FilterSupportedFeaturesMode

2. Disable ODX for the comparison:

Set-ItemProperty HKLM:\SYSTEM\CurrentControlSet\Control\FileSystem -Name FilterSupportedFeaturesMode -Value 1

Restart the Windows server during the agreed maintenance window. Repeat the same operation under a similar load and record the result. Changing the registry value alone does not establish that the previous transfer actually used ODX.

3. Restore the previous setting after the test. If it was 0, use:

Set-ItemProperty HKLM:\SYSTEM\CurrentControlSet\Control\FileSystem -Name FilterSupportedFeaturesMode -Value 0

Also schedule a restart after restoring the configuration. Run the disable and restore commands at separate stages, not one immediately after the other before testing.5

Walkthrough · 1:42. Analysing SMB disconnections in NetScope Viewing shares and SMB2 traffic.

04Disk Health Scan in DriveTime

Before assessing the NAS from a file transfer to or from a computer, take a local measurement. Disk Health Scan in DriveTime lets you observe drives during a test performed on the server. This removes SMB or iSCSI file-transfer speed from the measurement. The result still depends on NAS load, storage configuration and caching behaviour.

Preparation and execution

Record the server's state before testing: active tasks, CPU load, memory usage and disk activity. Where this will not disrupt users, pause unnecessary tasks for the measurement. Note which services were stopped; do not directly compare an idle NAS with one running a backup.

Caution: these tests place a load on the storage and may slow down services. Volume tests, read tests included, write a test file to the volume and need space for it. Do not keep running tests on an unstable array merely to obtain a more conclusive report.

  1. Open DriveTime Analyzer → Speed and select the volume in the title bar.
  2. Select a test type. Volume tests include sequential and random reads or writes, a mixed test and FULL REPORT. Volume tests, read tests included, first write a test file (4 GB by default) to a temporary folder on the selected volume and remove it when the test finishes or is stopped. Read-only disk scan reads the block devices one at a time and then in parallel; the test itself does not write to the drives being examined.
  3. Click the start button for the selected mode, such as Analyze, Write test, Mixed test or FULL REPORT. Write tests, the mixed test and FULL REPORT display a confirmation message. Read it before starting the measurement.
  4. When the test finishes, select Save report (.md). The report is saved in the Public share as report-ioutils-storagediag-utilities-<date>-<time>.md, with an accompanying trace file ending in -trace.csv. You can also open saved results through Disk reports in the Start menu.

“Read-only” describes the test, not the entire NAS. The operating system and other applications may still perform their own writes. Each scan phase runs for the set duration (30 seconds by default), so it is not a complete scan of every sector.

The Speed tab before a measurement. Current drive await values appear at the top, with Disk Health Scan settings below. Read-only disk scan is selected; the description below the form explains the components of the test duration.
Walkthrough · 1:26. Testing local storage performance in DriveTime The Speed tab; the measurement was taken after stopping the services specified in the example.

Reading latency and queue statistics

await is the average time taken to complete an I/O request, including both time in the queue and service time. A high value may reflect a heavy workload rather than a fault. Compare it with IOPS (input/output operations per second), throughput and queue length.6

Do not derive the actual time spent on a drive's mechanical operations solely from await and device utilisation. System statistics describe requests observed by the operating system; without additional data, they cannot reconstruct every operation inside the drive.7

In the per-drive tables, the median, p95 (95th percentile) and maximum are taken over one-second average await values; the read-only scan adds per-I/O percentiles from fio. If p95 is many times higher than the median, some recorded values differ substantially from the typical result. This does not establish the cause. Check when the spikes occurred and what the NAS was doing at the time.

A drive handling more operations than its peers may have a longer queue. Conversely, low throughput with apparently ordinary latency requires checking whether the device was actually receiving a comparable workload. This is why individual and parallel tests are useful, together with SATA logs and SMART readings from the same period.

Assessing the report and deciding what to do next

The OK, WATCH and SUSPECT ratings help identify devices that need attention. The combined report also includes an OK, WARNING or CRITICAL rating and, in multi-phase tests, the phase in which a significant deviation was recorded. These ratings reflect the diagnostic rules applied by the tool; they are not, on their own, confirmation of a failed component.

Review the individual drive results, SMART readings before and after the test, kernel messages and the measurement trace together. In the example below, high latency on one drive occurs alongside reallocated sectors and a change in the G-sense counter. This combination warrants a closer investigation than a transfer-rate result alone.

If there are no signs of a fault, repeating the measurement under similar conditions can show whether the deviation is reproducible. If new drive errors appear, do not increase the load with further attempts: protect the data and investigate the fault.

The report in the Reports window. The report identifies device sdf in bay 14 as needing attention; the largest deviation occurred during sequential reads. In this example, p95 is twelve times the median, the reallocated-sector count is 369, and the G-sense counter increased during the test. This is the same drive whose history and SMART readings were shown earlier.
Walkthrough · 1:55. Identifying a drive with abnormal results in an array The full DriveTime report, drive comparisons and SMART changes.

Reports for technical support and AI analysis

Attach the Markdown report, CSV trace and the NAS diagnostic ZIP bundle to the support case. Describe the transfer direction, protocol, client computer and tasks running during the test. This information helps establish the conditions under which the measurement was taken.

Before sending logs to an AI service, check which data will be sent externally. Reports may contain device names, network addresses, serial numbers, share names and other infrastructure details. Remove sensitive information that is not needed for the analysis. An API key does not, by itself, mean that processing is local or that data is automatically anonymised.

You can paste the Markdown report into an AI assistant yourself. Separately, the ✨ button in the Kernel Log and Dr. Trace windows analyses the logs of the loaded diagnostic bundle. It uses the service configured under Access management → AI keys. It shows the full prompt first, which you can edit; nothing is sent until you click Send.

Treat an AI response as assistance with interpretation. Check any recommendation to replace a drive, change the configuration or delete data against the original results and documentation.

05Fragmentation, space usage and drive speed

Fragmentation in QTS and QuTS hero

In QTS with ext4, the Disk Map tab shows information about the distribution of data and free space. Select a volume, then Scan. Sample limits the analysis to a specified duration; Full analyses the entire directory tree within the selected scope. A sample result may not represent all files on the volume.

The Fragmented files indicator is a score from 0 to 100 calculated from the file analysis, not a percentage of files. The program describes 0–30 as no fragmentation problem, 31–55 as moderate and 56 or above as heavy fragmentation. Its rating does not guarantee that fragmentation has no effect on a particular application. The significance of the result also depends on how the data is accessed.

In QuTS hero with ZFS, Read pool examines the distribution of free space in the pool. Do not equate this result with the ext4 file fragmentation score. These are different types of analysis, not two versions of the same indicator.8

Disk Map is an analysis tool. A scan does not move blocks or perform defragmentation.

Space usage: check both the volume and the pool

Keep spare capacity available. An 80% warning threshold is a useful point at which to review space usage, not a claim that every configuration suddenly slows down after another percentage point is used. In QuTS hero, the pool alert threshold is configurable.9

In QTS, check both the free space in the volume and pool capacity used by volumes, snapshots and reservations. In QuTS hero, examine pool free space, snapshots, and share or LUN limits. Do not directly add percentages calculated against different total capacities.

In ZFS, higher space usage and fragmented free space can make allocating space for new writes more difficult. The effect on performance depends on the workload and pool layout; utilisation alone does not determine the speed of every share.8

Why defragmentation is not the first step

Moving or rewriting data can increase space requirements when snapshots retain the old blocks. This does not mean that every byte moved always doubles physical space usage in every configuration. The outcome depends on factors such as the snapshot mechanism, the extent of the changes and how the data is stored.10

DriveTime does not perform defragmentation. First check space usage, workload and test results. Freeing space helps with subsequent writes, but does not automatically make existing fragmented files contiguous. Do not run an arbitrary defragmentation tool on an active NAS pool.

Datasheet speed versus file-copy performance

An HDD's advertised sequential speed does not describe every workload. On a single drive, performance depends heavily on I/O size, access order, reads versus writes and the need to move the heads. An array adds RAID level, workload distribution, caching and concurrent tasks.

Do not treat one figure, such as 100–120 MB/s, as the correct result for every drive. That rate may be good in one scenario and too low in another. Compare the same type of test over a similar area and under similar conditions, and check specifications for the exact model.

Disk Map shows the distribution of data or free space, Speed shows storage behaviour under load, and Health shows drive health history. Use these findings together to connect a drop in transfer rate with a possible cause.

Disk Map for a volume on a single HDD with 94% of its capacity used. The result comes from a 60-second sample. The map shows space usage and the distribution of remaining free space; it is not a measurement of drive speed. The file list has been omitted from the image.
Walkthrough · 0:35. Analysing fragmentation and free space in Disk Map Distinguishing ext4 file analysis from a ZFS pool free-space map.

06Network

An iperf3 test measures data transfer between two devices without copying a file from the volume under investigation. A standard test does not measure SMB or iSCSI performance. It can still be limited by the CPU, operating system and configuration at either end of the connection, not just by the cable or switch.11

  1. On the NAS, open Utilities → NetScope → Bandwidth → Server. In the configuration described here, the iperf3 server starts listening, on port 5201 by default. Check the displayed interface and address; use Network interface to select the connection to test.
  2. On a second NAS, select NetScope → Bandwidth → Client. Choose a device from the list or enter its address in Manual target, then click Start Test. On Windows, you can use NetScope-latest.exe, available through the link in the NetScope title bar.
  3. Record the test direction, interfaces used and result. Test both directions: in the NetScope client, use Direction. In command-line iperf3, -R selects server-to-client transfer; by default, data flows from the client to the server.
  4. When finished, click Stop Listener and wait for “Listener stopped.”, then close the window. Do not expose the test port to the Internet; restrict any firewall rule to the device performing the measurement.
NetScope in Bandwidth → Server mode. In the configuration shown, the iperf3 server listens on all interfaces on port 5201. Stop Listener ends the listener; closing the window sends a stop request. Network addresses have been masked.
Walkthrough · 0:28. Measuring network throughput with NetScope An iperf3 test using NetScope and the Windows client.

A low iperf3 result calls for checks of the connection and both devices: negotiated port speeds, interface errors, cables, switches, routing, VPN connections and CPU load. It does not prove that all storage problems have been ruled out.

A good iperf3 result with slow file copying means you should also look beyond the connection's throughput: protocol handling, storage, the application or the client computer. Compare results over the same network path.4

Keep the units distinct: 1 Gb/s is 125 MB/s before overhead, not 1 GB/s. The transfer rate for user data is lower than the link's nominal bandwidth.

ADrives in a NAS: the basics

Choosing drives for RAID and continuous operation

Select drives for the specific NAS model, drive count and workload. The label NAS, Pro or Enterprise does not define every specification. Check the exact model, recording technology, support for continuous operation, annual workload rating and device compatibility.3, 12

Read-error handling also matters in an array. TLER/ERC mechanisms limit how long the drive attempts its own data recovery so that the RAID system can respond. An excessively long response can trigger a timeout and cause the device to be removed from the array. However, there is no single timeout shared by all controllers, drives and configurations. Check support and settings for the particular model, not the entire “desktop” category.12, 1

CMR and SMR

In CMR, recording tracks do not overlap in the way characteristic of SMR. Updating data on an SMR drive may require additional housekeeping and rewriting of larger areas. Buffering can temporarily reduce the effect on performance, but latency may increase substantially during sustained or random writes.13

This does not mean that every individual overwrite immediately rewrites an entire zone, or that every SMR drive will be removed from a RAID array. Behaviour depends on the drive design and workload.

For a conventional NAS RAID array, choose compatible CMR drives, especially when predictable rebuild behaviour matters. Host-managed SMR requires specific support and is not a drop-in replacement for an ordinary SATA drive in any NAS.13, 12

Drive class and intended use
Class or intended useTypical applicationWhat to check before installation
NASFile shares, backups and continuous operation in a multi-drive serverHCL, CMR/SMR, workload rating, supported configurations and error-recovery mechanisms.
NAS ProHeavier multi-drive workloads and more usersThe exact model's specifications; “Pro” does not imply one universal TB/year rating or bay-count limit.
EnterpriseServers and storage arrays within the drive manufacturer's specified requirementsInterface and sector-format compatibility, firmware, workload and operating conditions.
SurveillanceRecording video streamsSupport in the particular NAS and suitability for workloads other than video recording.
ArchivingStoring data that changes infrequentlyRecording technology, sustained write behaviour and data-retrieval requirements. “Archive” is not synonymous with SMR.
DesktopComputer workloads covered by the model's specificationContinuous operation, workload, error handling and suitability for the intended RAID. Do not assume compatibility merely because the drive uses SATA.

Do not compare only spindle speed and capacity. Two drives in the same family may differ in technology, firmware or workload rating. Neither MTBF nor the annual workload rating tells you how many years an individual drive will last.12

SMART: attribute meanings and appropriate action

SMART helps detect problems, but does not predict a failure date. Track values over time and compare them with logs and symptoms. The SATA names below are common; their interpretation can depend on the manufacturer and drive type.2

SMART attributes and NVMe fields
ID or fieldMeaningWhat to checkStorageDiag default: warning / critical
5 — Reallocated_Sector_CtSectors replaced with spare sectors.Whether the backup is current, whether the counter is increasing and whether other drive errors are present.≥ 1 / ≥ 50
197 — Current_Pending_SectorSectors with read problems awaiting resolution.Data protection and further diagnostics; do not try to “repair” them by running a write test over user data.≥ 1 / ≥ 5
198 — Offline_UncorrectableErrors the drive could not correct during the relevant tests.The test log, read errors and backup status.≥ 1 / ≥ 1
187 — Reported_UncorrectReported uncorrectable errors.Counter increases and related I/O errors.≥ 1 / ≥ 10
196 — Reallocation_Event_CountEvents associated with sector reallocation.The manufacturer's interpretation and changes in attribute 5.≥ 1 / ≥ 20
10 — Spin_Retry_CountHDD spindle spin-up retries.Power supply, start-up behaviour and the condition of the drive's mechanical components.≥ 1 / ≥ 10
188 — Command_TimeoutCommands that exceeded their timeout.The drive, communication path, power and firmware; the counter alone does not identify one cause.≥ 1 / ≥ 100 (decoded value)
199 — UDMA_CRC_Error_CountTransmission errors on the SATA link.Counter increases, connectors, connections and the backplane; do not equate these errors with media damage.≥ 1 / ≥ 100
194 — Temperature_CelsiusTemperature reported by the drive.The model's permitted range, airflow and temperature under load.≥ 55 °C / ≥ 65 °C
NVMe — Percentage UsedAn estimate of the proportion of the drive's expected endurance already consumed.The trend and replacement planning; 100% is not, by itself, a failure notification.≥ 80% / ≥ 100%
NVMe — Media and Data Integrity ErrorsUncorrectable data or integrity errors.The backup, error log and further diagnostics; not every entry indicates NAND damage alone.≥ 1 / ≥ 10
NVMe — Critical WarningA bit field describing specific warning conditions.Which bit is set: for example, temperature, available spare capacity, degraded reliability or read-only mode.any bit set: critical

NVMe fields have their own definitions. In particular, Percentage Used can exceed 100%, and Critical Warning must be decoded rather than treated as an ordinary error counter.14

DriveTime warning thresholds are not the same as the Thr column read from the drive. The former are classification rules in the tool; the latter is reported by the firmware. The last column of the table above gives the default thresholds of the SMART window and the DriveTime drive card in StorageDiag 1.6.10045; an administrator can change them. They are not the drive manufacturer's thresholds. DriveTime describes the rules of the version in use under How verdicts work → Rules & formulas. History alerts on the Health tab use separate rules.

On some Seagate models, large raw values in attributes 1, 7 or 195 result from the way the data is encoded. Do not automatically interpret them as millions of errors. Check the model-specific interpretation, normalised values and other diagnostic evidence; do not dismiss other warnings merely because the drive is made by Seagate.2

Respond to read errors in RAID even while the array is still working. A rebuild depends on successfully reading the required data from the remaining drives. Further errors can prevent recovery of some data or the entire group, depending on the RAID level and extent of the problem. A backup remains necessary regardless of array redundancy.

SSD caching, SLOG and backup power

SSD caching, SLOG and protection
MechanismPurposeProtection
QTS: read-only cacheStores additional copies of data to accelerate reads.A UPS helps prevent an uncontrolled shutdown of the entire NAS.
QuTS hero: L2ARCAn additional read-cache layer on SSDs.It is not a write cache; a UPS still protects server operation.
QTS: write-only or read/write cacheMay hold new data before it is written to the destination drives.Protection against power loss and cache-drive failure is required.
QuTS hero: SLOGA separate device for the ZFS synchronous-operation log.Choose suitable SSDs with PLP and a fault-tolerant configuration, such as a mirror; also configure a UPS.

In QTS, losing a write-cache drive can mean losing data not yet written to the destination storage. Choose a supported configuration that protects against drive failure. Single, JBOD and RAID 0 do not provide that protection.15

SLOG is not a general-purpose write cache. ZIL is the ZFS intent log; SLOG provides a separate device for it. The log allows the required operations to be replayed after a crash. During normal operation, data is written from RAM to the main pool; SLOG does not necessarily improve performance for workloads that do not issue synchronous writes.16

PLP (Power Loss Protection) in a drive and a UPS protect at different levels. A UPS gives the server time to shut down safely during an external power failure, but does not protect against every internal failure. PLP does not replace backups or protection against complete drive failure. After connecting a UPS, configure the NAS's response to a power outage and check communication with the UPS.17, 16

When diagnostics are complete, keep the results and a description of the conditions for each test. Your conclusion should identify which measurements and log entries support the suspected cause, not merely which component received the lowest rating.

Technical sources

  1. Linux Kernel, libATA Developer’s Guide, sections on transmission errors and error handling.
  2. smartmontools, smartctl documentation on vendor-specific attributes and normalised, raw and threshold values.
  3. QNAP, drive and device compatibility list.
  4. Microsoft Learn, Slow SMB files transfer speed, covering the effects of the client, buffering, file sizes and security.
  5. Microsoft Learn, Deploy Windows Offloaded Data Transfers; registry-value definitions.
  6. sysstat, iostat documentation and definitions of await, aqu-sz and %util.
  7. Linux Kernel, I/O statistics fields.
  8. OpenZFS, zpoolprops, including the fragmentation, capacity and free properties.
  9. QNAP, creating a storage pool in QuTS hero h6.0.x and configuring its alert threshold; an example using an 80% threshold.
  10. OpenZFS, Copy-on-Write.
  11. ESnet, Invoking iperf3.
  12. Western Digital, WD Red Pro family description and specifications, as an example of model-dependent parameters.
  13. Western Digital, On WD Red NAS Drives, 23 June 2020: a discussion of CMR, SMR and rebuild behaviour, not a current model catalogue.
  14. Microsoft Learn, NVME_HEALTH_INFO_LOG.
  15. QNAP, Creating the SSD Cache, describing cache modes and the risk of configurations without protection against drive failure. Check the available options for the installed QTS version.
  16. OpenZFS, Caching and Auxiliary Devices.
  17. QNAP, How to avoid sudden shutdown from power outage?